cable cervicom eapsp multicore 14mm cpr

Multi-core cable for railway infrastructures, used as signalling cables. Installation in a gutter or directly buried (cover with special protection against rodents).

See only CPR
See by cable type
See by fire behaviour

If you need technical support complete the form or call us at (+34) 937 362 730

Support
Cable Cervicom EAPSP Multicore 1,4mm CPR
~\ImgCli\FOTO2_283.jpg
Multi-core cable for railway infrastructures, used as signalling cables. Installation in a gutter or directly buried (cover with special protection against rodents).
Protegido electromagneticas
Anti roedores
Resistente agua
Enterrado directo
Technical characteristics
1. Min. bending radius
15xD
2. Operating Tª (conductor)
Operaction: -25°C to +75°C
3. Insulation resistance
Min. 35000 MOhm*Km (500V, 20°C)
4. Conductor resistance
Medium Value: 11,2±0,5 Ohm/Km
Maximum Value: 11,9 Ohm/Km
5. Dielectric strength
Cond-Cond: 3000 V
Cond-Screen: 5000 V
Construction
1. Conductor
Bare copper wire
Diameter: 1,4mm
2. Insulation
Solid high density polyethylene
3. Assembly
In concentric layers
Enclosure: Polyester tape to the set
4. Outer sheath
Polyethylene (UV Resistant)
Colour standard: Black
5. Inner sheath
Polyethylene
Colour standard: Black
6. Overall screen
Copolymer coated aluminium tape, longitudinal, overlapped and adhered to the inner PE cover
7. Armour
Copolymer-coated corrugated steel strip, logitudinally positioned and overlapped
8. Individual assembly
Insulated conductors
Standards
1. CPR Classification (Euroclass)
Fca
Standards / Properties
1. Ref. standard for drawing
ADIF ET-03.365.051.6 (2ª Ed)