cat 7a cable cervicom data sftp lshf cpr

Shielded Category 7A halogen free data transmission cable for local area networks (LAN) in fixed installations, both dry and wet.

See only CPR
See by cable type
See by fire behaviour

If you need technical support complete the form or call us at (+34) 937 362 730

Support
Cat. 7A - Cable Cervicom DATA S/FTP LSHF CPR
~\ImgCli\FOTO2_1357.jpg
Shielded Category 7A halogen free data transmission cable for local area networks (LAN) in fixed installations, both dry and wet.
No propagador de la llama
Libre halogenos
Technical characteristics
1. Weight
55 Kgs/Km
2. Outer diameter
7,8 mm
3. Min. bending radius
Fixed installation (without load): 4xD
During installation (with load): 8xD
4. Conductor resistance
73 Ohm/Km (20°C)
5. Operating Tª
Fixed installation: -20°C to +60°C
During installation: 0°C to +50°C
6. Characteristic Impedance
100 ± 15 Ohm (1-250 MHz)
100 ± 20 Ohm (250-500 MHz)
100 ± 25 Ohm (500-1000 MHz)
Construction
1. Conductor
Bare copper wire
23 AWG (0,58mm Aprox.)
2. Insulation
Foam polyethylene
Nominal diameter: 1,38mm
3. Assembly
4 individually shielded twisted pairs laid up together
4. Composition
Two insulated conductors twisted together as a pair
5. Overall screen
Tinned copper wire braid
6. Individual screen
Aluminium/Polyester tape on each pair
7. Outer sheath
Halogen free compound
Colour: Orange
Standards
1. CPR Classification (Euroclass)
Dca-s2,d2,a2
(According to UNE-EN 50575)
Standards / Properties
1. Flame Retardant
UNE-EN 60332-1 (IEC 60332-1)
2. Halogen free
UNE-EN 60754-1 (IEC 60754-1)
3. Low smoke emission
UNE-EN 61034 (IEC 61034)
4. Ref. standard for drawing
IEC 61156-5; ISO 11801; EN 50173; ANSI/TIA-568-C