cable cervicom profibus dp chain cable chains

Extra flexible bus cable for data transmission systems (Profibus DP) in industrial processes in dynamic installations, such as cable chains (horizontal installations)

See only CPR
See by cable type
See by fire behaviour

If you need technical support complete the form or call us at (+34) 937 362 730

Support
Cable Cervicom Profibus DP CHAIN (Cable chains)
~\ImgCli\FOTO2_1772.jpg
Extra flexible bus cable for data transmission systems (Profibus DP) in industrial processes in dynamic installations, such as cable chains (horizontal installations)
Protegido electromagneticas
Profi bus
No propagador de la llama
Libre halogenos
Hidrocarburos
Flexible
Cadenas portacables
Resistente aceites
Resistente agua
Construction
1. Conductor
Extra flexible bare copper wires
Cross sectional area: AWG24 (0,25mm2)
2. Insulation
Foam polyolefin
Nominal diameter: 2,55mm
Colours: Red, Green
3. Assembly
Two insulated conductors twisted together as a pair (eventual fillers)
4. Screen
Aluminium/polyester tape
Coverage: 100%
+
Tinned copper wire braid
Coverage: 80%
5. Outer sheath
PUR (Polyurethane)
Colour: Violet (RAL 4001)
Technical characteristics
1. Operating voltage
30 V
2. Test Voltage
500 V
3. Operating Tª
-40°C +80°C (Fixed installation, dynamic installation and storage)
4. Min. bending radius
6xD
5. Mutual capacitance
30 pF/m
6. Characteristic Impedance
150 Ohm
7. Transmission speed
12 Mbit/s (200m maximum length)
0,6 kbit/s (1000m maximum length)
8. Conductor resistance
81 Ohm/Km Max.
9. Insulation resistance
200 MOhm*Km Min.
10. Maximum chain speed
250 m/min
11. Maximum acceleration
30 m/s2
12. Maximum chain length
15 m (only horizontal)
13. Flexible life
6.000.000
Standards / Properties
1. Reference standards
UL File No: E83517
UL 80°C 30V - CSA AWM I/II A/B 80°C 30V
2. Flame Retardant
UL VW-1 - CSA FT1 - IEC 60332-1 - CEI 20-35
3. Halogen free
CEI 20-37 - IEC 60754-1
4. Oil and hydrocarbon resistant
UL 1581 - VDE 0472 part 803 A/B - HD 22.10 S1 - CNOMO E.03.40.150N
5. Water resistant
UL 1581 - IEC 60811