Cable Cervicom DeviceNet Thin
~\ImgCli\FOTO2_935.jpg
Flexible data transmission BUS cable for fixed installations in industrial processes such as Device Net BUS Thin cable
Protegido electromagneticas
No propagador de la llama
Hidrocarburos
Flexible
Resistente aceites
Construction
1. Conductor
Flexible tinned copper wires (0,12mm)
Gauge: AWG24
2. Insulation
Foamed polyolefin
Nominal diameter: 2,0mm
Identification: White, Blue
3. Individual screen
Aluminium/polyester tape over each pair
4. Assembly
2xAWG24 shielded + 2xAWG22 shielded laid up together + tinned copper drain wire
5. Overall screen
Tinned copper wires braid
Coverage: 80% Min.
6. Outer sheath
PVC
Colour: Violet (RAL 4001)
Technical characteristics
1. Conductor resistance
92 Ohm/Km Max. (AWG24) / 59 Ohm/Km Max. (AWG22)
2. Insulation resistance
200 MOhm*Km Min.
3. Test Voltage
500 V
4. Operating voltage
30 V
5. Nominal capacitance
46 pF/m
6. Characteristic Impedance
120 Ohm Nom.
7. Operating Tª
-20°C +80°C
8. Min. bending radius
5xD
Standards
1. Reference standards
UL File No: E83517
UL/CSA - UR (UL Recogmnised Component):
· UL AWM Style 2502
2. Flame Retardant
CEI 20-35 ; EN 50265 ; IEC 60332-1 ; UL VW-1 ; CSA FT1
3. Oil and hydrocarbon resistant
UL 1581 ; VDE 472 part 803 A/B ; HD 22.10 S1 ; CNOMO E.03.40.150N