cable encoder resolver cerviflex pepur c

Combinated shielded power and control cable, specially designed for Encoder-Resolver. Extra-flexible and with high resistance to abrasion and bending in dynamic installations, suitable for use in energy chains when good electromagnetic protection is necessary. The outer cover made of special polyurethane provides additional protection against abrasion, hydrolysis and the most

See only CPR
See by cable type
See by fire behaviour

If you need technical support complete the form or call us at (+34) 937 362 730

Support
Cable Encoder-Resolver CERVIFLEX PE/PUR-C
~\ImgCli\FOTO2_1078.jpg
Combinated shielded power and control cable, specially designed for Encoder-Resolver. Extra-flexible and with high resistance to abrasion and bending in dynamic installations, suitable for use in energy chains when good electromagnetic protection is necessary. The outer cover made of special polyurethane provides additional protection against abrasion, hydrolysis and the most common chemical agents and oils.
Protegido electromagneticas
No propagador de la llama
Libre halogenos
Hidrocarburos
Desina
Cadenas portacables
Resistente aceites
Resistente agua
Resistente productos químicos
Technical characteristics
1. Operating voltage
300 V
2. Test Voltage
2000 V
3. Min. bending radius
Fixed installation: 5xD / In movement cable: 7,5xD
4. Operating Tª (conductor)
-40°C to +80°C
5. Bending cycles, max.
6.000.000
6. Maximum chain speed
300 m/min
7. Maximum acceleration
50 m/s²
8. Maximum chain length
10 m (horizontal)
Construction
1. Conductor
Extra flexible bare copper wires
Class VI Acc. to UNE-EN 60228
2. Insulation
Polyolefin and polyester (UL-CSA Standards)
Identification: See table
3. Assembly
Overall cabling of all the elements with possible fillings in the interstices + wrap of non-woven tape on the set
4. Composition
Combined colours:
· See table "Formation"
5. Overall screen
Braid of tinned copper wires
Coverage: 85%
+ wrapping of non-woven tape on the screen
6. Individual screen
· See table "Formation"
7. Outer sheath
Polyuethane (UL-CSA Standards)
Green RAL 6018 according DESINA
8. Individual sheath
· See table "Formation"
Standards / Properties
1. Ref. for construction/drawing
According UL 758, UL 1581 and CSA 22.2 210.2
(UL 80° 300V - CSA AWM I/II A/B 80°C 300V)
2. Flame Retardant
UNE-EN 60332-1 (IEC 60332-1) ; CEI 20-35 ; UL VW-1 ; CSA FT1
3. Halogen free
UNE-EN 60754-1 (IEC 60754-1) ; CEI 20-37
4. Oil and hydrocarbon resistant
UL 1581 ; VDE 0472 part 803 A/B ; HD 22.10 S1 ; CNOMO E.03.40.150N
5. Water resistant
UL 1581 ; IEC 60811