Cat. 5e - Cable Cervicom DATA F/UTP LSHF PATCH (Flexible)
~\ImgCli\FOTO2_1278.jpg
Flexible halogen-free shielded cable for Category 5e data transmission in local area networks (LAN), suitable for the work area (computers) and panel wiring.
No propagador de la llama
Libre halogenos
Humos baja opacidad
Flexible
Baka corrosividad gases
Technical characteristics
1. Test Voltage
1000 V (DC, 1 min)
2. Weight
25 Kg/Km
3. Outer diameter
5,4 mm
4. Min. bending radius
Fixed installation (without load): 20mm
During installation (with load): 40mm
5. Insulation resistance
5000 MOhm*Km Min. (500V)
6. Characteristic Impedance
100 ± 5 Ohm (at 100 MHz)
7. Velocity of propagation
67%
8. Operating Tª
Fixed installation: -20°C to +60°C
During installation: 0°C to +50°C
9. Resistance unbalance
3% Max.
10. Capacitance unbalance
1200 pF/Km Max. (Pair-Ground)
11. Loop resistance
260 Ohm/Km Max.
12. Mutual capacitance
Nominal 48 pF/m (at 800Hz)
13. Propagation delay
Nominal 535 ns/100m
14. Transfer Impedance
-
15. Coupling attenuation
55 dB Min.
16. Segregation class
50 mOhm/m Max. at 1MHz
100 mOhm/m Max. at 10MHz
200 mOhm/m Max. at 30MHz
Construction
1. Conductor
Stranded Bare copper wires
Diameter: 0,48 mm (AWG26/7)
2. Insulation
Polyethylene
Diameter: 0,95 mm
3. Composition
4 twisted pairs laid up together
4. Overall screen
Aluminium/polyester tape + tinned copper drain wire (AWG26)
5. Outer sheath
Halogen free compound
Standard colour: Grey (RAL 7035)
Standards / Properties
1. Flame Retardant
UNE-EN 60332-1 (IEC 60332-1)
2. Halogen free
UNE-EN 60754 (IEC 60754)
3. Low smoke emission
UNE-EN 61034 (IEC 61034)
4. Ref. standard for drawing
TIA/EIA 568-B.2; ISO/IEC 11801; IEC 61156-6; EN 50173-1; EN 50288-2-2